The following tables describes the information generated by the plugin.
In order to get temperature(s) of your system, you can run the plugin from the command line or through the configuration file:
$ bin/fluent-bit -i thermal -t my_thermal -o stdout -m '*'
Fluent Bit v1.x.x
* Copyright (C) 2019-2020 The Fluent Bit Authors
* Copyright (C) 2015-2018 Treasure Data
* Fluent Bit is a CNCF sub-project under the umbrella of Fluentd
* https://fluentbit.io
[2019/08/18 13:39:43] [ info] [storage] initializing...
...
[0] my_thermal: [1566099584.000085820, {"name"=>"thermal_zone0", "type"=>"x86_pkg_temp", "temp"=>60.000000}]
[1] my_thermal: [1566099585.000136466, {"name"=>"thermal_zone0", "type"=>"x86_pkg_temp", "temp"=>59.000000}]
[2] my_thermal: [1566099586.000083156, {"name"=>"thermal_zone0", "type"=>"x86_pkg_temp", "temp"=>59.000000}]
Some systems provide multiple thermal zones. In this example monitor only thermal_zone0 by name, once per minute.
$ bin/fluent-bit -i thermal -t my_thermal -p "interval_sec=60" -p "name_regex=thermal_zone0" -o stdout -m '*'
Fluent Bit v1.3.0
Copyright (C) Treasure Data
[2019/08/18 13:39:43] [ info] [storage] initializing...
...
[0] my_temp: [1565759542.001053749, {"name"=>"thermal_zone0", "type"=>"pch_skylake", "temp"=>48.500000}]
[0] my_temp: [1565759602.001661061, {"name"=>"thermal_zone0", "type"=>"pch_skylake", "temp"=>48.500000}]
[INPUT]
Name thermal
Tag my_thermal
[OUTPUT]
Name stdout
Match *
pipeline:
inputs:
- name: thermal
tag: my_thermal
outputs:
- name: stdout
match: '*'